Industrial Injection and Blow Molding HVAC Air Conditioner Cooling Air Cooled Scroll Chiller
Product Details
Our company has introduced many sets of advanced processing equipment and technology to expand the processing capacity of our Indoor Air Quality, High ESP Ducted Fan Coil Unit, R22. Since the establishment of our company, after years of hard work, we have the advantages of development, advanced technology and complete equipment. Our company pursues sustainable development by maintaining the relationship with customers. We stay with the basic principle of 'quality initially, services first, steady improvement and innovation to fulfill the customers' for your management and 'zero defect, zero complaints' as the quality objective. We pursue clear processes, effective systems and clear division of responsibilities and powers in management to achieve high quality, high efficiency and low consumption in management.
Air cooled scroll chiller is a cost-effective and stable-running HVAC solutions. It’s a small packaged chiller that maximum 16 units can be combined in one system to make a single larger capacity. Air cooled scroll chiller is one of the most traditional HVAC solutions.Air cooled scroll chiller consists of compressor, condenser, expansion device, and evaporator. Air cooled modular chiller has smaller size than standard chillers, It takes less space for installation.Moreover,There is less downtime if one of the modules malfunctions because each module has its own dedicated power to keep running.
Main features:
1. Intelligent defrosting program
Defrosting starts only when the unit need to reducing defrosting time and water temperature fluctuation.
2. Modular design
Max. 32 units can be combined in one group (16 units for 130kW units), max. capacity can be up to 2080kW.
3. Unit back-up function If master unit fails, all the units will stop and any of the slave units can be set as master unit manually. If one slave unit fails, this unit will stop but others keep running.
4.Built-in water flow switch
Standard with high quality water flow switch.Convenient for installation, no need to install water flow switch in water system on site.Realise the function of control every chiller’s water flow precisely
5. High efficiency shell&tube heat exchanger
Shell&tube heat exchanger uses spiral turn-back design and high heat transfer efficiency copper pipes, to avoid rectangular place of dead heat, decrease water pressure drop, improve heat exchange
6. Parallel running system
Efficiency will be increased 12% when one compressor full load running because the condenser area is 2 times than independent running system.
Refrigerant circuit will be simpler and running condition will be more stable.
Independent running system/ Paralel running system
7. Smart motor speed control
Two-speed control independently guarantees the best condenser condition and low consumption.
In part load running condition, the motor will run in low speed and with low consumption
8.Cycle operation
In one combination system, according to unit’s accumulated operation time, all slaver units operates as alternative in cycle, which increases reliability and balances units lifespan.
9.Wide operation range
Operate from -15˚C to 46˚C without failure
10.Unique control logic
When a system with four units running at part load and 4 compressors are needed, in ordinary control logic two units will run at full load but in AIRMYTH control logic, four compressors in four units will run to make full use of all condensers, so the efficiency improves a lot.
11.Round-designed condenser
360° air intake The airflow is evener and heat exchange is more sufficient.
12.CTIG inner-grooved copper tube Higher thermometric conductivity and increases heat-exchanging efficiency.
13.Cross flow fins Low air resistance and great heat transfer coefficient, and frosting improves a lot.
14.Multiple protections
15.High Cooling Performance EER
30KW 60KW 130KW
EVI Modular Chiller
High heating performance
Low temperature heat pump unit adopts EVI technology. Two-stage compression improves heating capacity and efficiency in low ambient temperature.
EVI compressor
Low-temperature heat pump unit adopts EVI (Enhanced Vapor Injection) compressor. A part of drawn intermediate pressure gas refrigerant mixes and compresses with compressed refrigerant, which realizes two-stage compression in one compressor, increases compression efficiency and improves the heating performance in low temperature.
Plate heat exchanger
Plate heat exchanger plays an important role in EVI heat pump unit. Sub-cool the refrigerant before throttling in primary loop, increase enthalpy difference. Preheat the throttled refrigerant in auxiliary loop, supply gas refrigerant to compressor for secondary compression.
Wide operation range
Cooling operating temperature is up to 46℃ Heating operating temperature is down to -30℃
Air-cooled heat pump modular chiller
High Reliability Copeland compressor
Better Liquid Handling Radial compliance allows the scroll members to seperate in the presence of liquid refrigerant,thus, providing protection against luquid damage. Greater Efficiency With axial compliance,optimized force between two scrolls can be obtained,leading to high efficiency over the entire operating range. Unmatched Reliability Ability to start under any system load,without start components. Easy to service and maintain Easy to service and maintain due to their compact size and light weight. Simple design Engineered for optimun performance with todays’s chlorine-free refrigerants.No complex internal suction and discharge valves for quieter operation and higher reliability.
Eco friendly R410A(HFC) refrigerant,low carbon footprint,no harm to the environment.
Larger loading quantity
Optimized structure and compact size provided a larger load quantity,for a 20’container,65kW unit could be loaded 12 sets,and 130kW can be loaded 6 sets.
500 steps EXV from famous brand
Compare to TXV,it controls refrigerant flow as per operation mode and temperature condition,because EXV has faster load reaction speed,bigger regulation range,higher refrigerant control accuracy,so the water outlet temperature can be controlled more precisely
Modular design concept
Modular design concept,a good solution for agencies to make stocks.Excellent flexibility in installation,max.16 units can be combined in a group,max.capacity can be up to 2080kW
Precise temperature control
Precise water perperature control,keeps room temperature stable.compressors in each units auto respond to the real capacity needs ,system provides precisely water temperature controls.
Optimize fan blade design
Optimization of fan blade and fan shroud design,bigger air flow,lower noise.
Balance operation program
Balance operation program,it balances the operation time of every unit according to the unit’s accumulated operation time
Backup function
If master unit fails all the units will stop,any one of the slave units can be set as master unit manually.if one slave unit fails,this unit will stop but others keep running.
Wide operation range
R22,R410a
R407C
Multi Protections
Comprehensive protections to guarantee system’s safety.
Using various protection devices to guarantee the system more safe and reliable.
High pressure switch
Low pressure switch
Compressor current protection
Phase protection
Spiral turn-back plate heat exchanger
The refrigerant flow in traditional bow shaped turn-back flow heat exchanger moves in”Z” path.The new spiral flow design in spiral turn-back plate heat exchanger changes the status and form of refrigerant,thus increasing heat exchange efficiency. The main characteristics of spiral turn-back plate heat exchanger are as below:
1.high heat transfer coefficient(20%~40% increase); 2.Full coverage of heat exchange.without dead heat;
3.Obvious decrease of pressure drop in the shell(around 45% drop pressure under the same flow velocity);
4.Few impurities are no retention area in the shell; 5.Better anti-vibration
High efficiency condenser Refrigerant flow paths are optimized design,especially for the lower part of condenser coil,it evens the heat exchange between upper part and lower part of condenser ,to improve the efficiency of whole unit,also improve the defrosting efficiency in cold winter.
High efficiency evaporator
High efficiency shell & tube evaporator,fouling factor is 0.086m2 *℃/kW,high heat transfer efficiency copper pipes are used in the heat exchanger
Modbus gateway Modbus gateway is built in the control logical for standard.it can realize BMS control without any device
Connection of pipe system
Over the past few years, because of the rapid development of the industry, our Industrial Injection and Blow Molding HVAC Air Conditioner Cooling Air Cooled Scroll Chiller needs to be constantly updated, the transformation of it is also constantly refined. We continue to follow the business philosophy of 'Quality, Innovation, Service, Responsibility', uphold the value of 'Achieving Customers, Achieving Employees', and work together with you to create greater glories! Welcome to inquire about our products.
Hot Tags: air cooled scroll chiller, China air cooled scroll chiller manufacturers, suppliers, factory, Linear Grille, One Way Cassette Fan Coil Unit, Indoor Air Quality, Air Purifier, Ceiling Concealed Fan Coil Unit, Air Cooled Scroll Chiller
Inquiry
You Might Also Like
-
Window Type Air Air Conditioner (JH18AP-18T8-1)
-
T3 Tropical Climate Refrigeration System Ducted Spli...
-
Cool Heat Pump Split Wall Mounted Air Conditioners 9...
-
Big Cadr Suitable for Home Office Hospital Use Air C...
-
Light Commercial Aluminum Square Ceiling Diffuser 3-...
-
Bulk-Buying Refrigerant Gas R407c Replacement of R22...